News
The main products are food additive microcrystalline cellulose, food additive magnesium stearate, food additive sodium carboxymethyl starch, food grade magnesium stearate, food grade sodium carboxymethyl starch microcrystalline cellulose, Magnesium stearate, sodium carboxymethyl starch, pregelatinized starch, starch, dextrin, etc.
04
2021
-
11
What are the precautions for using capsule fillers?
Precautions for using capsule filling machine: This equipment is a vibrator. Regularly check the fastening of all parts. If loose, tighten in time to prevent failure and damage.
Capsule FillerInstructions for Use:
1. This equipment is a vibrator. Regularly check the tightness of all component screws. If loose, tighten them promptly to prevent failure and damage.
2. Acrylic components (worktable and medicine tray) should be protected from direct sunlight and high temperatures. Do not place heavy objects on them. The medicine tray must be placed vertically or horizontally to avoid deformation and damage.
3. The electrical shell and body must be grounded to ensure safety. Turn off the power after work.
4. After each day's work, clean up any remaining medicine on the machine and in the mold holes, keeping the entire machine clean and hygienic. Avoid washing the main unit with water. If the mold on the machine needs cleaning, you can loosen and remove the fixing screws for easier installation.
Capsule FillerTroubleshooting:
1. Unsatisfactory vibration, adjust voltage.
2. If the reed screw is loose, tighten the screw. Capsule Filler
3. The capsule shell is set in the worktable, its mouth can move up and down. Adjust the height of the offset plate and guide rail.
4. Too many capsule shells are inverted (over 3%), improper adjustment of the vibrator. Qualified capsule shells are selected as the voltage adjustment is correct or the capsule shell size does not meet the specifications.
5. The capsule shell is stuck on the pressing plate and cannot fall off. Replace the capsule shell or adjust the position of the offset plate and pressing plate hole. Capsule Filler
6. The mold cannot be reset in the track, the compression spring at the rear end of the guide rail is stuck or the capsule is deformed and stuck. Reinstall the spring or pusher rod and use the pusher to push down the stuck cassette.
7. The guide plate in the mold is worn, affecting the low capsule filling rate. Replace the new mold or the lateral positioning is loose. Tighten the positioning pins. If the cassette is deformed or damp, replace the cassette shell. Capsule Filler
The filling station mainly controls the filling weight of the capsule contents, which is an important link. The main problem is that the weight of the filling material is unstable. According to experts, the main reasons for this problem are as follows.
1. The pre-weighing tray is not aligned with the lower module. Misalignment here leads to incomplete transfer of the drug into the capsule during filling, resulting in lighter weight of some finished capsules. Capsule Filler
2. The gap between the isolation block and the metering plate on the metering plate is too large. The role of the isolation block is to separate the tamped drug from other drugs in the filling powder ring when the drug in the metering plate is tamped and transferred to the filling station.
3. The height of the powder on the metering plate also has a certain impact on the filling quality. The powder height is controlled by a sensor in the powder ring, with a spiral feeding rod continuously adding powder above it, maintaining a constant powder height in the powder ring.
There are many precautions when cleaning the capsule filler online. Because the capsule filler is prone to dust leakage when cleaning the equipment after production, online cleaning is one of the main measures to ensure closed production.